The Honeywell L4064B2228 Fan and Limit Controller provides dependable temperature regulation and safety protection for warm air furnace systems.
Designed for accurate fan control and overheat protection, the Honeywell L4064B2228 combines fan and limit functions in one compact, durable unit. With a 5-inch insertion element, it senses plenum temperature to control blower fan operation and act as a high-limit safety cutoff. Factory-set fan and limit temperatures ensure reliable performance, system safety, and occupant comfort.
- Model numberL4064B2228identifies theHoneywell Fan and Limit Controllerfeaturing a5-inch insertion elementwith fixed temperature settings.
- Designed forwarm air furnacesto regulate blower operation and provide high-temperature limit protection.
- Combinesfan controlandlimit safety controlfunctions into one precision-engineered device.
Technical Data & Performance
- Product TypeFan and Limit Controller.
- Element Length5 inches– suitable for compact furnaces and standard residential plenum installations.
- Fan Control SettingsFan On125°F (52°C)Fan Off100°F (38°C).
- High Limit Setting200°F (93°C)– automatically shuts off the burner to prevent overheating.
- Switch ConfigurationSPST fan switch / SPST limit switchcombination for dual control functionality.
- Electrical Ratings: Supports8A at 120V AC(resistive load); suitable for standard furnace fan and burner circuits.
- Application: Controlsblower fan operationand serves as ahigh-limit safety cutoffin warm air furnaces.
- Sensing ElementCoiled bimetal sensordesigned for precise temperature response and long-term stability.
- Differential: Factory-set fan differential for optimized blower cycling and comfort.
- ConstructionMetal sensing elementwith a durable plastic enclosure for temperature stability and reliability.
- Mounting TypeSurface mountwith insertion probe extending into furnace plenum for direct temperature sensing.
- Reset TypeManual reset on high limitfor additional system safety.
- Operating Voltage120V ACstandard.
- Ambient Temperature Range40°F to 190°F (-40°C to 88°C).
- Function: Turns blower on when plenum reaches set temperature, turns it off when cooled, and shuts down burner at high limit.
- Safety Function: Prevents heat exchanger damage and furnace overheating by cutting power to the burner when limit temperature is exceeded.
- InstallationSimple retrofit or OEM installationwith accessible adjustment dials and secure terminal connections.
- Compliance: MeetsUL and CSA standardsfor HVAC system safety controls.
- MaintenanceLow-maintenance designinspect periodically during furnace servicing.
- Dimensions5-inch insertion lengthstandard control housing with adjustable mounting bracket.
- Warranty: Backed byHoneywell’s Limited Manufacturer’s Warrantyfor performance and reliability.
Specifications
Buying Information
Confirm the listed Honeywell L4064B2228/U size, configuration, and application match before ordering.