The MARS 83915 Side-Open A/C Disconnect provides a safe and convenient means to disconnect air conditioning and refrigeration equipment, featuring a 60-amp non-fused design for 120/240-volt systems.
The MARS 83915 A/C Disconnect is engineered for reliability and ease of installation in residential and light commercial HVAC applications. Designed with a side-opening door for accessible servicing, this non-fused disconnect safely isolates power to air conditioners, condensers, and heat pumps. Constructed from durable, weather-resistant materials, it meets NEC requirements for line-of-sight disconnects and ensures dependable performance in outdoor environments. Rated at 60 amps and 120/240 volts, it is suitable for most single-phase HVAC systems.
- Model number83915identifies theMARS Side-Open Non-Fused Air Conditioner Disconnect.
- Designed forair conditioning and refrigeration service disconnectionin residential or light commercial applications.
- Non-fused configurationprovides power isolation while maintaining circuit protection via upstream breaker.
Technical Data & Performance
- Product TypeAir Conditioner Disconnect (Non-Fused).
- BrandMARS.
- Model83915.
- Ampere Rating60 Amps.
- Voltage Rating120/240 VACsingle-phase.
- Frequency60 Hz.
- Number of Poles2-Pole(double line-break design).
- Disconnect TypePull-out handle, non-fused.
- Enclosure TypeSide-open metal housingwith removable pull handle.
- Enclosure RatingNEMA 3R– outdoor-rated, rainproof construction for weather resistance.
- Door TypeSide-opening hinged doorprovides easy access to internal components.
- Mounting TypeWall-mounted surface installation.
- Wire Size Compatibility: Accepts up to#6 AWG copper or aluminum conductors.
- KnockoutsTop and bottomknockouts for flexible conduit entry.
- Operating Temperature Range40°F to 140°F (-40°C to 60°C).
- MaterialGalvanized steel enclosurewith corrosion-resistant powder coat finish.
- FinishGray powder-coated exteriorfor durability and weather protection.
- Cover DesignSide-hinged access doorfor convenient service disconnecting.
- Safety Features
- Non-fused configurationprevents accidental energization while servicing equipment.
- Pull-out disconnect handleensures positive power interruption.
- UL-listed componentsensure compliance with electrical safety standards.
- Compliance
- MeetsNEC Article 440requirements for air conditioning disconnects.
- Complies withUL 1429andCSA C22.2certification standards.
- Rated forResidential HVAC installationsunder local electrical codes.
- Dimensions (Approximate)
- Height8.5 inches.
- Width5 inches.
- Depth2.75 inches.
- Weight~2.5 lbs (1.13 kg).
- Mounting HardwareNot included– compatible with standard exterior-grade fasteners.
- Application EnvironmentOutdoor-rated enclosurefor wall or structure-mounted HVAC equipment.
- MaintenanceLow maintenanceperiodic inspection of terminals and housing recommended.
- Packaging: Supplied as asingle disconnect unitwith pull-out handle and enclosure.
- Warranty: Backed byMARS Limited Manufacturer’s Warrantyfor materials and workmanship.
Applications & Benefits
- Providessafe and accessible power disconnectionfor A/C units, condensers, and heat pumps.
- Non-fused designsimplifies maintenance and reduces replacement part costs.
- Side-opening access doorallows easy servicing and inspection.
- Durable NEMA 3R metal enclosureresists corrosion and weather damage.
- Ideal forresidential, multifamily, and light commercial HVAC installations.