Bradford White 415-43676-03 – Resettable High-Limit Safety Switch, 290°F Manual Reset
The Bradford White 415-43676-03 is a high-limit, manual reset thermal cutoff switch engineered for safety-critical applications in atmospheric vent gas water heaters. Designed to open at 290°F, this device functions as a secondary over-temperature protection mechanism to interrupt gas flow in the event of abnormal heat accumulation.
This component is commonly integrated into select Bradford White models and mounted on the outer jacket or burner chamber area. Its resettable feature allows system restoration without part replacement, provided the underlying cause has been resolved.
Product Function and Use
This switch monitors localized temperature and is intended to interrupt the thermocouple circuit upon reaching its trip point. Restoration requires manual reset, providing an added layer of safety to prevent cycling under fault conditions. The 290°F version (identified by its red housing) is typically specified for use in high-temperature tolerance applications across various residential water heater models.
Specifications
- Manufacturer Part Number415-43676-03
- Trip Temperature290°F (143°C)
- Reset TypeManual (requires technician intervention)
- Switch TypeNormally closed, opens on high temperature
- Terminal Connection1/4” quick-connect spade terminals
- MountingSurface mount using integrated bracket
- Color IdentificationRed housing for quick field identification
Installation and Service Considerations
This device must be installed in accordance with OEM specifications and applicable codes. Prior to replacement or reset, service technicians should verify that combustion air, venting, and burner operation are functioning correctly. Installation requires standard hand tools and should be performed with the appliance powered down and gas isolated. Improper reset or reuse of a tripped device without diagnosing the cause may result in unsafe operation or repeated failure.
Professional Application Notes
- ✔Use as OEM Replacement OnlyDo not substitute with lower trip-point devices unless specified by Bradford White.
- ✔Failure ModesCommon causes of thermal switch trip include flue blockage, burner assembly faults, or restricted combustion air intake.
- ✔Inspection PointDuring annual maintenance, verify terminal condition and thermal switch bracket integrity.
Compatible Units
The 415-43676-03 is used in select gas-fired Bradford White residential water heaters where a 290°F limit switch is specified. Always confirm model compatibility using technical service documentation or the appliance serial number and tag data.