TheDiversiTech® 7-CRNR35is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.
Engineered for System Longevity and Compliance
This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.
Key Technical Advantages
- Amperage Rating35 A
- Voltage Rating250 VAC
- Interrupting Rating200,000 A RMS Symmetrical
- ConstructionDual element, time delay
- ClassRK5 per UL 248-12
Performance Features
- ✅Dual Element Time Delay– Allows temporary overloads typical of motor startups without compromising protection.
- ✅RK5 Certification– Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
- ✅High Interrupt Capacity– Rated for 200kA to safely isolate high fault currents.
- ✅Consistent Arc-Quenching– Reduces potential damage to downstream components in fault scenarios.
Installation Considerations
Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.
Contractor Use Cases
For licensed HVAC and electrical contractorsThe 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.
Compliance and Standards
- UL ListedUL 248-12, Class RK5
- CSA CertifiedCSA C22.2 No. 248.12
Professional Summary
TheDiversiTech® 7-CRNR35 Dual Element Time Delay Fuseis an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.
Contractor-Grade Overcurrent Protection – DiversiTech® 7-CRNR35 RK5 Dual Element Time Delay Fuse
TheDiversiTech® 7-CRNR35is a dual-element time delay fuse designed to safeguard HVAC and motor-driven systems from short circuits and prolonged overloads. With a Class RK5 classification and a 200,000 A interrupting capacity, this fuse supports high fault current environments while minimizing nuisance tripping during inrush conditions.
Engineered for System Longevity and Compliance
This 35A, 250VAC-rated fuse is purpose-built for demanding electrical applications such as air conditioning and refrigeration systems, motor control circuits, and other inductive loads. The dual-element design delivers superior protection during motor startup while preserving system uptime.
Key Technical Advantages
- Amperage Rating35 A
- Voltage Rating250 VAC
- Interrupting Rating200,000 A RMS Symmetrical
- ConstructionDual element, time delay
- ClassRK5 per UL 248-12
Performance Features
- ✅Dual Element Time Delay– Allows temporary overloads typical of motor startups without compromising protection.
- ✅RK5 Certification– Meets the performance requirements for industrial fusing applications requiring short-circuit protection.
- ✅High Interrupt Capacity– Rated for 200kA to safely isolate high fault currents.
- ✅Consistent Arc-Quenching– Reduces potential damage to downstream components in fault scenarios.
Installation Considerations
Installation of the 7-CRNR35 should be completed by a qualified electrician or HVAC technician. Ensure compatibility with fuse holders rated for Class RK5 fuses and verify circuit parameters against nameplate data. Always de-energize equipment prior to replacement.
Contractor Use Cases
For licensed HVAC and electrical contractorsThe 7-CRNR35 supports reliable operation across a range of motor-driven loads, with added protection during startup. It’s a cost-effective solution that reduces callbacks due to unnecessary tripping and minimizes equipment exposure to short circuit damage.
Compliance and Standards
- UL ListedUL 248-12, Class RK5
- CSA CertifiedCSA C22.2 No. 248.12
Professional Summary
TheDiversiTech® 7-CRNR35 Dual Element Time Delay Fuseis an essential protective component for high-load HVAC and motor applications. It ensures coordinated circuit protection, minimizes service disruptions, and meets the demands of professional environments requiring robust overcurrent mitigation.
Specifications
Buying Information