Campbell / ATS Quartz Sleeve for DWS-7 / SE-7 UV Systems
Replacement quartz sleeve for the Campbell / Aqua Treatment Services (ATS) ultraviolet disinfection systems model DWS-7 and SE-7 (rated for 6-7 gpm). The quartz sleeve encloses the UV lamp, protecting it from water contact while enabling UV transmission to disinfect the flowing water.
- Part number / modelATS6-211(often listed as “Quartz Sleeve for DWS/SE7”):contentReference[oaicite:0]{index=0}
- Compatible systems: Campbell / ATS DWS-7, SE-7, and related UV units in the DWS / SE line:contentReference[oaicite:1]{index=1}
- Flow rating: Intended for use in systems handling up to 6–7 gallons per minute (gpm):contentReference[oaicite:2]{index=2}
- Dimensions
- Length: 378 mm (≈ 14.88 in):contentReference[oaicite:3]{index=3}
- Inside diameter: 22 mm:contentReference[oaicite:4]{index=4}
- Outside diameter: 24.5 mm:contentReference[oaicite:5]{index=5}
- Ends: Open on both ends (for lamp insertion and compression sealing):contentReference[oaicite:6]{index=6}
- Material: High-quality UV-grade fused quartz (optimized for UV transmission and thermal stability):contentReference[oaicite:7]{index=7}
- Function
- Isolates the UV lamp from direct water contact while allowing ultraviolet light (254 nm) to pass through for disinfection.
- Helps maintain a consistent lamp operating temperature and protects against shorting / electrical issues.:contentReference[oaicite:8]{index=8}
- Sealing / Mounting
- Uses compression end nuts and O-rings at each end for a watertight seal within the threaded chamber ends.:contentReference[oaicite:9]{index=9}
- Quartz sleeve is installed through the stainless steel chamber and slightly protrudes beyond each end nipple before securing compression nuts.:contentReference[oaicite:10]{index=10}
- Maintenance & Replacement
- Recommended cleaning frequency: once monthly in normal conditions (or as needed depending on water quality):contentReference[oaicite:11]{index=11}
- Replacement interval: typically change quartz sleeve when lamp is changed (annually) or every 24 months as needed based on wear / clouding / damage.:contentReference[oaicite:12]{index=12}
- When removing, loosen compression nuts carefully (avoid overtightening or applying torque with tools to prevent fracture):contentReference[oaicite:13]{index=13}
- After removal, clean with mild soap / water; more aggressive cleaning (e.g. weak acid) may be used if mineral deposits are present, following safety procedures.:contentReference[oaicite:14]{index=14}
- Replace O-rings each time the sleeve is removed / serviced to maintain seal integrity.:contentReference[oaicite:15]{index=15}
- Operational Constraints & Notes
- Handle quartz sleeve with care — avoid touching surfaces with bare fingers (oil deposits degrade UV transmission).:contentReference[oaicite:16]{index=16}
- Ensure water conditions (turbidity, hardness, minerals) do not degrade performance—excess deposits reduce UV transmissivity.:contentReference[oaicite:17]{index=17}
- Ensure proper alignment, straight installation, and avoid stresses on the sleeve during chamber assembly.:contentReference[oaicite:18]{index=18}
- Quartz sleeve must remain intact — any chips or cracks will impair UV performance or lead to failure.
- Weight: ~ 0.01 lb (package listing):contentReference[oaicite:19]{index=19}
- Warranty: Usually 1-year manufacturer warranty on quartz sleeve parts, subject to proper handling and installation.:contentReference[oaicite:20]{index=20}
Technical & Performance Notes
- The quartz sleeve must maintain high UV transparency at 254 nm to allow the UV lamp’s germicidal output to pass into the water stream effectively.
- Any fouling, clouding, or scaling of the quartz surface will reduce UV dose delivered and can compromise disinfection performance.
- When replacing, the quartz sleeve must align concentrically with the lamp and chamber to minimize eccentricity, which could cause nonuniform UV exposure or lamp stress.
- Because the UV systems are rated for up to 7 gpm, the sleeve design supports adequate UV exposure time within that flow regime (i.e. optical path length and sleeve wall thickness are chosen accordingly).
- Always follow manufacturer’s procedural steps for installation, leak testing, and UV lamp insertion to preserve system integrity and warranty.
Specifications
Buying Information
Confirm the listed Non-Specified Brand ATS6-211 model and configuration before ordering.